FEATURES
Control Modules
Single zone pumping unit, multizone pumping unit, zone controller
Rated capacity (lbs/h)
220
441
106
1014
1323
Power supply
230 V, 1 phase, 50 Hz or 208 V, 1 phase, 60Hz
Pumping unit power consumption kW
0.955
0.955
1.15
1.15
1.95
Zone controller power consumption kW
0.28
Operating Conditions
34 to 104 °F <80% RH non-condensing
Storage Conditions
34 to 122 °F <80% RH non-condensing
Index of protection
Type 1
Certifications
Hygienic certification for air-conditioning generic applications
VDI 6022, page 1 (04/06), VDI 3803 (10/02), ONORM H 6021 (09/03), SWKI VA104-01 (04/06), DIN EN 13779 (09/07)
Hygienic certification for hospital applications
DIN 1946, part 4 (01/94), ONORM H 6020 (02/07)*, SWKI 99-3 (03/04)
Certification
CE and ETL998 (pumping unit); ETL508A (zone controllers)
Water inlet
Connection
G3/4”F (NPT3/4F for UL versions)
Temperature limits
34 to 104 °F
Pressure limits
43.5 to 116 psi
Total hardness (ppm CaCO3)
0 to 25
Conductivity limit  µS/cm
0 to 50 µS/cm (stainless steel pump) – 30 to 50 µS/cm (brass pump)
pH
6.5 to 8.5
Water outlet
Connection
M16.5m DIN 2353 (G3/8”F) (NPT3/8F for UL versions)
Water drain
Connection
Stainless steel pipe, OD 10 mm/ 0.4 inch
Serial communication
CAREL, Modbus® protocol (others optional)
Control
Control
External signal, temperature or humidity control; plus temperature or humidity limit probe
Type of input signals
0 to 1 V, 0 to 10 V, 2 to 10 V, 0 to 20 mA, 4 to 20 mA, NTC
Dimensions and weights
Pumping unit dimensions (LxWxH) inches
40.5x15.7x33.8
Pumping units weight lbs.
187
187 209 209 220

Zone controller dimensions (LxWxH) inches

19.6x5.9x22.8
Zone controller weight lbs.
43
 
*: In accordance with H6020 (02/07), chapter 6.13.2 is demanded in Austria the use of steam humidifiers or equivalent humidification systems.
 
 
 