Industrial and Commercial Humidifiers
    and OEM HVAC/R Controls

 
AIR CONDITIONING CONTROLS REFRIGERATION CONTROLS HUMIDIFIERS
HumidCalc Rep Locator Product Demonstrations Literature Product Registration Secure Rep Area
 
 Electrode Steam Humidifier
» product overview
» product data
» Literature

VAC/
Phase

Factor

UNIT MODEL NUMBER: Capacity, Amperage, Kilowatts

UE 001

UE 003

UE 005

UE 008

UE 009

UE 010

UE 015

UE 025

UE 035

UE 045

UE 045

UE 065

UE 090

UE 130

208/1 (U)

Lbs/hr

3.3

6.6

11.0

 

19.1

 

kg/h

1.5

3

5

8.7

Amps

5.4

10.8

18.0

31.3

KW

1.12

2.25

3.75

6.52

230/1 (D)

Lbs/hr

3.3

6.6

11.0

19.8

kg/h

1.5

3

5

9

Amps

4.9

9.8

16.3

29.3

KW

1.12

2.25

3.75

6.75

208/3 (W)

Lbs/hr

 

6.6

11.0

17.6

 

22

33

55

77

 

99

 

kg/h

3

5

8

10

15

25

35

45

Amps

6.2

10.4

16.7

20.8

31.2

52.0

72.9

93.7

KW

2.25

3.75

6.00

7.50

11.25

18.75

26.25

33.75

230/3 (K)

Lbs/hr

6.6

11.0

17.6

22

33

55

77

99

kg/h

3

5

8

10

15

25

35

45

Amps

5.6

9.4

15.1

18.8

28.2

47.1

65.9

84.7

KW

2.25

3.75

6.00

7.50

11.25

18.75

26.25

33.75

460/3 (M)

Lbs/hr

6.6

11.0

17.6

22

33

55

77

99

 

132

198

286

kg/h

3

5

8

10

15

25

35

45

60

90

130

Amps

2.8

4.7

7.5

9.4

14.1

23.5

32.9

42.4

61.2

84.7

122.4

KW

2.25

3.75

6.00

7.50

11.25

18.75

26.25

33.75

48.75

67.50

97.50

575/3 (N)

Lbs/hr

 

11.0

17.6

22

33

55

77

99

132

198

286

kg/h

5

8

10

15

25

35

45

60

90

130

Amps

3.8

6.0

7.5

11.3

18.8

26.4

33.9

49.0

67.8

97.9

KW

3.75

6.00

7.50

11.25

18.75

26.25

33.75

48.75

67.50

97.50

Height

24.4” (620 mm)

28.0” (710 mm)

35.0” (890 mm)

37.2" (945mm)

37.2" (945mm)

Width

14.4” (365 mm)

14.4” (365 mm)

21.9” (555 mm)

25.6" (650mm)

45.5" (1156mm)

Depth

10.8” (275 mm)

10.8” (275 mm)

14.2” (360 mm)

17.9" (455mm)

17.9" (455mm)

Dry weight

35.3 lbs (16 kg)

44.0 lbs (20 kg)

75.0 lbs (34 kg)

97.0 lbs (44 kg)

160 lbs (73 kg)

Wet weight

41.9 lbs (19 kg)

59.5 lbs (27 kg)

133.4 lbs (60.5 kg)

207.2 lbs (94 kg)

330 lbs (150 kg)

Max. water feed

0.16 gpm (0.6 l/min)

0.32 gpm (1.2 l/min)

1.06 gpm (4.0 l/min)

1.85 gpm (7 l/min)

4 gpm (15 l/min)

Water feed connection

3/4” MPT (19 mm) bushed to 1/4” O.D. compression

Max. drain rate

1.32 gpm (5 l/min)

6.0 gpm (22.5 l/min)

12 gpm (45 l/min)

Drain connection

1.6" hose (40mm)

Min. drain piping

¾” (19 mm)

1 ½” (38 mm)

No. cylinders

1

2

Steam outlet (No.x size)

1 x 22/30 mm

1 x 30 mm

1 x 40 mm

2 x 40 mm

4 x 40 mm

Control voltage

24 VAC 50/60 Hz.

Ambient conditions

34-140°F (1-40°C), 0-80 % RH, up to 8 inches W.C. duct static pressure (200 mm W.C.)

Feed water conditions

15 – 116 psi (1-8 bar), 125-1250 MicroMhos conductivity

Ventilated steam distributors

VSDU0A

VRDXL (One (1) required for each steam outlet. i.e. four (4) for UE130)

Power: 24 volt powered by unit

Power: 220/1/50-60, 35 Watts

Air volume: 112 cfm (192 m3/h)

Air volume: 380 cfm (646 m3/h)

Height/Remote: 6.3/10.75” (160.273 mm)

Height = 10.5” (267 mm)

Weight: 13.2 lbs. (6 kg)

Weight: 63 lbs. (24 kg)

Noise: 30 dBA (50)

Noise: 40 dBA


Model Selection

UE

025

H

D

000

U

1

0

UE = Electrode

Capacity

H Control

Power supply

Version number

USA

Cylinder Type

Optional Equipment

001 = 3.3 lbs/hr

For use with:

U = 208/1

Internal use only

 

1 = Disposable Standard Conductivity

0 = Standard

003 = 7 lbs/hr

On/off

D = 230/1

005 = 11 lbs/hr

or

W = 208/3

2 = Disposable Low Conductivity

B = Direct Mount Blower

008 = 18 lbs/hr

Modulating

K = 230/3

010 = 22 lbs/hr

or

M = 460/3

015 = 33 lbs/hr

DDC

N = 575/3

025 = 55 lbs/hr

035 = 77 lbs/hr

045 = 99 lbs/hr

065 = 132 lbs/hr

 
 
Copyright © 2006 CAREL USA. All Rights Reserved.
Home     Contact Us    Careers    Sitemap
webmaster@carelusa.com