Technical Specifications
Main connection
Input Voltage Vin 380 to 500 V, -15%,,,+10% 3 ~
Input Frequency 45 to 66 Hz
Mains connection once a minute or less (normal conditions)
Motor connection
Output voltage
0-Uin
Continuous output current
IH:
Peak torque
150% (low overload); 200 % (high overload) 2s each 2s
Output frequency
0 to 320 Hz
Frequency resolution
0.01Hz
Control Features
Control Method V/f frequency control "Sensorless"open loop vectorial control
Frequency reference: analog input, panel reference Resolution 0.1 % (10 bits), accuracy ±% Resolution 0.01 Hz
Field-weakness area 30 to 320 Hz
Acceleration time 0.1 to 3000 s
Deceleration time 0.1 to 3000 s
Braking torque DC braking 30%*CN (without brake option)
Environmental conditions
Operating temperature -14°F (no frost) to 122°F: IH;
°-14 °F (no frost) to 104°F: IL
Storage temperature -40°F to 158°F
Relative humidity 0 to 95%, non-condensing, non-corrosive, without dripping water

Air quality:
chemical fumes
mechanical particles

IEC 721-3-3, unit operating, class 3C2
IEC 721-3-3, unit operating, class 3S2
Altitude 100 % load capacity up to 1000m. 1% reduction in the specifications for each 100m above 1000m; max. 3000m
Vibrations:
EN50178/EN60068-2-6
5 to 150 Hz
Amplitude: 1mm (peak) to 5 to 15.8 Hz
Max acceleration amplitude: 1 G to 15.8G to 150 Hz
Impact:
EN50178/EN60068-2-27
UPS drop test (for applicable UPS weights)
Storage and shipment: max. 15G, 11 ms (with packaging)
Index of protection IP20: MF2 and MF3, IP21/54: MF4, MF5 and MF6
EMC
Immunity Satisfies all immunity requirements: EN 61800-3
Emissions MF2-MF3: EMC level N; with external filter RFI (optional), EMC level H MF4-MF6: EMC level H: EN 61800-3 (1996) + A11 (2000) 1st environment, restricted distribution 2nd environment: EN 61000-6-4- EMC level C: see chapter 2.2.3
Safety
EN50178, EN60204-1, CE, UL, CUL, FI, GOST R, CEI 61800-5 (see rating plate motor for further details on the conformity)
Control Connections
Analog input voltage 0 to 10 V, Re =200kΩ , Resolution 0.1%, accuracy ±1%
Analog input current 0 (4) to 20 mA, Re =200kΩ differential
Digital inputs (3) Positive or negative logic; 18 to 24 Vdc
Auxiliary voltage +24V, ±15%, max. 100 mA
Ref. output voltage +10V, +3%, max. load 10mA
Analog output 0 (4) to 20mA; RC max. 500Ω; 16 bit resolution: accuracy ±1%
Relay output 1 programmable relay output - Switching power: 24VDC/8A, 250VAC/8A, 125VDC/0.4A
Protectors
Protection against voltage surges
Protection against voltage drops
NXL_2: 437 Vdc; NXL_5: 911 Vdc
NXL_2: 183Vdc; NXL_5: 333Vdc
Earth fault protection In the event earth faults in the motor or the motor cable, only the inverter is protected.
Protection against excess temperature Yes
Motor overload protection Yes
Motor stall protection Yes
Motor underload protection Yes
Short-circuit protection for reference voltages +24V and +10V Yes
 
 
 