EVD*200_EVD*4*
Product relation: pCO3, pCO1, pCOxs, pCOC
The EVD*300 and EVD*400 driver control the refrigerant superheating, managing many of the stepper electronic expansion valves on the market.
It is possible to use both these drivers in both air conditioning or refrigeration applications. Moreover, the driver features a rechargeable back-up battery. |
Documentation
| Part Number |
Description |
Type |
Language |
Date |
Release |
| +050003830 |
|
technical leaflet |
ITA/ENG |
11/23/2004 |
1.4 |
| +050003875 |
PID controller with driver for two pole stepper valve |
technical leaflet |
ALL |
11/6/2006 |
2.4 |
|
|
| |
Literature is not available |
LonWorks® serial card (PCO10000F0)
PCO10000F0
Product relation: pCO3, pCO1, pCOXS, pCOC
PCO10000F0 card is used to interface to a LonWorks® network. The type of interface on the LonWorks® network side is: PCO10000F0 - interface to FTT-10 A 78 kbs (TP/FT-10). The baud rate must be set to 4800. |
|
| |
 |
pCOnet RS485 interface board
PCO1000BA0
Product relation: pCO3, pCO1, pCOXS, pCOC
Used to interface the pCO controllers with the BACnet™ and RS485 protocols, emerging standards in the HVAC industry. |
Documentation
| Part Number |
Description |
Type |
Language |
Date |
Release |
| +050000930 |
pCOnet PCO1000BA0 - BACnet® MS/TP interface board for pCO |
technical leaflet |
ITA/ENG |
7/25/2006 |
1.1 |
|
|
| |
 |
pCO Web Ethernet™ interface board
PCO1000WB0
Product relation: pCO3, pCO2, pCO1, pCOXS, pCOC
Used to interface the pCO controllers with the BACnet™ and SNTP protocols, emerging standards in the HVAC industry. |
Documentation
| Part Number |
Description |
Type |
Language |
Date |
Release |
| +050003238 |
pCOWeb |
technical leaflet |
ITA/ENG |
3/8/2005 |
1.0 |
|
|
| |

Literature is not available |
TREND serial board
PCO100CLP0
Product relation: pCO3, pCO2, pCO1, pCOC
Provides communication with the TREND interface, a commonly-used building management system in English-speaking countries. For information and orders please contact trend@carel.com. |
|
| |
 |
FieldBus serial board
PCO100FD10
Product relation: pCO3, pCO1
Allows RS485 communication in FieldBus serial with a compatible external electronic device. |
Documentation
| Part Number |
Description |
Type |
Language |
Date |
Release |
| +050003270 |
PCO100FD10-PCOS00FD20-PCOS00HBF0 |
technical leaflet |
ITA/ENG |
5/26/2004 |
1.0 |
|
|
| |
 |
RS232 serial card
PCO100MDM0
Product relation: pCO3, pCO1, pCOXS, pCOC
PCO100MDM0 card is used to interface directly to a standard HAYES modem. The following hardware signals can be managed: output, "request to send" (RTS) in parallel to "data terminal ready" (DTR); input, "carrier detect" (CD). The maximum baud rate is 19200 baud. |
Documentation
| Part Number |
Description |
Type |
Language |
Date |
Release |
| +050003240 |
|
technical leaflet |
ITA/ENG |
1/30/2002 |
1.0 |
|
|
| |
 |
MP-BUS Board (PCO100MPB0)
PCO100MPB0
Product relation: pCO3, pCO1
Provides communication with a compatible external electronic device using the MP-BUS protocol. |
Documentation
| Part Number |
Description |
Type |
Language |
Date |
Release |
| +050003270 |
PCO100FD10-PCOS00FD20-PCOS00HBF0 |
technical leaflet |
ITA/ENG |
5/26/2004 |
1.0 |
|
|
| |
 |
tLAN serial board (PCO100TLN0)
PCO100TLN0
Product relation: pCO3, pCO1
Provides communication with a compatible external electronic device using the CAREL tLAN proprietary protocol. |
Documentation
| Part Number |
Description |
Type |
Language |
Date |
Release |
| +050003270 |
PCO100FD10-PCOS00FD20-PCOS00HBF0 |
technical leaflet |
ITA/ENG |
5/26/2004 |
1.0 |
|
|
| |
 |
DC/DC module
PCO2DCDC00
Product relation: pCO3, pCO2, pCO1, pCOC
Thanks to the DC/DC power supply module, the entire range of pCO controllers can be powered using the 48 Vdc storage batteries that are typical of telephone applications. The input voltage can range from 21 to 58 Vdc, while the output voltage is 24±1 Vdc/0.7 A or 30±1 Vdc/0.6 A. DIN rail mounting is made possible by the 4 DIN module plastic container. |
Documentation
| Part Number |
Description |
Type |
Language |
Date |
Release |
| +050004020 |
|
technical leaflet |
ITA/ENG |
9/25/2001 |
1.2 |
|
|
| |
 |
I/O expansion boards
PCOE*
Product relation: pCO3, pCO2, pCO1, pCOXS
The expansion boards PCOE000TLN0 and PCOE0004850 belong to the pCO system family and have been designed to increase the I/O's on the pCO3, pCOXS, pCO1 and pCO2 controllers. A maximum of 5 expansion boards for each controller can be connected. |
Documentation
| Part Number |
Description |
Type |
Language |
Date |
Release |
| +050003265 |
|
technical leaflet |
ITA/ENG |
3/31/2004 |
1.1 |
|
|
| |
 |
RS485 serial card
PCOS004850
Product relation: pCO3, pCOXS, pCO1, pCOC
Used to interface directly to an RS485 network with optical isolation. The maximum baud rate available is 19200 baud (settable via software). |
Documentation
| Part Number |
Description |
Type |
Language |
Date |
Release |
| +050003237 |
BMS serial card for pCO controller |
technical leaflet |
ITA/ENG |
2/14/2005 |
1.0 |
|
|
| |
 |
USB/RS485 converter
PCOS00AKC0
Product relation: pCO3, pCO1, pCOXS, pCOC
Ensures USB/RS485 conversion for compatible external electronic devices. |
Documentation
| Part Number |
Description |
Type |
Language |
Date |
Release |
| +050003410 |
pCO Smart Key USB adaptor |
technical leaflet |
ITA/ENG |
10/28/2005 |
1.1 |
|
|
| |
 |
Programming key
PCOS00AKY0
Product relation: pCO3, pCO1, pCOXS, pCOC
A new universal programming key has been made for the pCO controllers. This is used to transfer the programs from the key to the pCO and vice-versa. |
Documentation
| Part Number |
Description |
Type |
Language |
Date |
Release |
| +050003420 |
PCOS00AKY0 - Smart Key |
technical leaflet |
ITA/ENG |
6/1/2006 |
1.2 |
|
|
| |
 |
Modem board
PCOS00FD20
Product relation: pCO3, pCO1
Used to interface the controller with a standard HAYES modem in FieldBus serial. |
Documentation
| Part Number |
Description |
Type |
Language |
Date |
Release |
| +050003295 |
PCOS00FD20 - RS232 FieldBus card for pCO1 and pCO3 |
technical leaflet |
ITA/ENG |
9/29/2005 |
1.0 |
|
|
| |
 |
CANbus board
PCOS00HBB0
Product relation: pCO3, pCO1, pCOXS, pCOC
Provides communication with a compatible external electronic device using the CANbus protocol. |
Documentation
| Part Number |
Description |
Type |
Language |
Date |
Release |
| +050000162 |
PCOS00HBF* (serial board for the fieldbus port) - PCOS00HBB* (serial board for the BMS port) |
technical leaflet |
ITA/ENG |
7/7/2005 |
2.1 |
|
|
| |
 |
CANbus board
PCOS00HBF0
Product relation: pCO3, pCO1
Provides communication with a compatible external electronic device using the CANbus protocol. |
Documentation
| Part Number |
Description |
Type |
Language |
Date |
Release |
| +050000162 |
PCOS00HBF* (serial board for the fieldbus port) - PCOS00GBB* (serial board for the BMS port) |
technical leaflet |
ITA/ENG |
7/7/2005 |
2.1 |
|
|
| |
 |
Interface for OEM series humidifiers
PCOU*
Product relation: pCO3, pCO1, pCOXS, pCOC
This interface is used to control the main parameters of the CAREL OEM humidifiers (water level and conductivity in the cylinder, TAM current power sensor) directly from the pCO system controllers. The values read by the special sensors are converted into signals that are compatible with the inputs on the control board. The board is managed by the software application running in the pCO controller. |
| Part Number |
Description |
| PCOUMI2000 |
CAREL OEM steam humidifiers interface, 4 DIN modules |
| PCOUCON000 |
Screw terminals for PCOUMI2000 |
| PCOUCON100 |
Spring terminals for PCOUMI2000 |
Documentation
| Part Number |
Description |
Type |
Language |
Date |
Release |
| +050000908 |
|
technical leaflet |
ITA/ENG |
7/21/1997 |
1.3 |
| +050003210 |
|
technical leaflet |
ITA/ENG |
1/13/2004 |
1.2 |
|
|
| |
 |
pLD large terminal
pLD
Product relation: pCO system
The competitive solution from CAREL for all those applications that require an affordable price and have limited space available for housing the terminal. The pLD large terminal has 4 digit, 8 buttons and 8 LEDs for alarm and status indications. |
| Part Number |
Description |
| PLD00LF400 |
pCO LED Display Large, green - 4 digit, 8 buttons - panel mount version |
Documentation
| Part Number |
Description |
Type |
Language |
Date |
Release |
| +050003922 |
PLD terminals |
technical leaflet |
ITA/ENG |
9/7/2005 |
1.0 |
| +302238301 |
pCO system: programmable graphic displays |
brochure |
ENG |
10/10/2005 |
1.0 |
| +302238321 |
pCO system: programmable controllers |
brochure |
ENG |
2/15/2006 |
1.0 |
|
|