optiMist

EC*
 
  • Plus

    - two areas that can be controlled by a single cabinet, without the need for a slave control panel: ideal for the application of direct and indirect Evaporative Cooling
    - energy saving and possibility to reduce the time of use of mechanical cooling
    - inverter that allows an accurate and efficient modulation
    - two modulation steps to increase the accuracy of applications in a single area
    - drainage valves and flushing cycles to avoid water stagnation
    - sterile materials used which do not contribute to bacterial growth
    - can be used with demineralized water, softened water or mains water
  • General characteristics

    optiMist is a humidifier and adiabatic evaporative cooler that, by atomizing water into small droplets, allows the latter to evaporate spontaneously, subtracting heat from the humidified air, which is cooled at the same time. The system consists of a cabinet, inside which there is a flap valve pump, with pressures up to 15 bar, and an atomized water distribution rack, to be installed inside the air treatment unit. The sophisticated control system managed by the pCO, which combines the action of the inverter (that regulates the speed and therefore the flow of the pump) and that of the two solenoid valves, which activate only the nozzles that are necessary, allowing the system to operate always at optimum pressure in a wide flow range. The two solenoid valves (placed inside the cabinet) divide the distribution into two independent steps, which can be simultaneously present on the same rack (acting one after the other sequentially) forming two steps of continuous modulation, or they can be separated in two different distribution systems, each with a single step, supplying two different areas: this is the typical case of the application of humidification + direct adiabatic cooling in the input duct and indirect adiabatic cooling in the output duct, with heat exchanger between the two air treatment units.
    The optiMist cabinet is available in the following capacities: 13, 26, 53, 106, 211, and 264 gallons/h. The distribution system can be selected from a large list of available codes, depending on the size of the duct and the atomization required. optiMist can be used with demineralized water, but also with mains water, as long as the unit is cleaned more frequently
 

Documentation

Technical

  • Manuals
    Code Description Language Date * Release
    Code +0300065FR
     
    Description optiMist: refroidissement par évaporation
     
    Language FRE 
     
    Date 05/12/2018
     
    Release 1.4
     
    Code +0300065ES
     
    Description optiMist: refrigeración evaporativa
     
    Language SPA 
     
    Date 05/12/2018
     
    Release 1.4
     
    Code +0300065EN
     
    Description optiMist: evaporative cooling
     
    Language ENG 
     
    Date 05/12/2018
     
    Release 1.4
     
    Code +0500065IE
     
    Description RACK - optiMist: Sistema di distribuzione/ Distribution system
     
    Language ENG  ITA 
     
    Date 30/07/2018
     
    Release 3.0
     

Commercial

  • Brochure
    Code Description Language Date * Release
    Code +3000054ES
     
    Description Soluciones para el ahorro energético en los data center
     
    Language SPA 
     
    Date 11/10/2016
     
    Release 2.0
     
    Code +3000054FR
     
    Description Solutions permettant d'économiser l'énergie dans les centres de données
     
    Language FRE 
     
    Date 11/10/2016
     
    Release 2.0
     
    Code +3000106EN_chillventa
     
    Description On Show - Chillventa 2016
     
    Language ENG 
     
    Date 08/10/2016
     
    Release 2.0
     
    Code +3000046FR
     
    Description optiMist: Refroidissement par évaporation et humidification
     
    Language FRE 
     
    Date 02/05/2012
     
    Release 1.0
     
    Code +3000046ES
     
    Description optiMist: Refrigeración evaporativa y humectación
     
    Language SPA 
     
    Date 02/05/2012
     
    Release 1.0
     
    Code +3000046EN
     
    Description optiMist: evaporative cooling and humidifying
     
    Language ENG 
     
    Date 02/05/2012
     
    Release 1.0
     

Local Information

  • Local Information
    Code Description Language Date * Release
    Code +30U0018EN (USA)
     
    Description Humidity Matters Brochure
     
    Language ENG 
     
    Date 19/02/2015
     
    Release 3.0
     
    Code +30U046EN
     
    Description optiMist - Evaporative cooling and humidifying
     
    Language ENG 
     
    Date 04/06/2013
     
    Release 1.1